UE-BBIC-TN1  Bus Bar Insulation Tee Interlaced Connection Cover / Bushing Boot up to 40.5kV

Product Details
Customization: Available
Application: Insulators, Electrical Winding Insulation, Electrical Base, Shell, Switch Baseplate
Material: Polyolefin
Diamond Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Years of Export Experience
The export experience of the supplier is more than 10 years
ODM Services
The supplier provides ODM services
OEM Services
The supplier provides OEM services for popular brands
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
to see all verified strength labels (23)
  • UE-BBIC-TN1  Bus Bar Insulation Tee Interlaced Connection Cover / Bushing Boot up to 40.5kV
  • UE-BBIC-TN1  Bus Bar Insulation Tee Interlaced Connection Cover / Bushing Boot up to 40.5kV
Find Similar Products

Basic Info.

Model NO.
UE-BBIC-TN1
Thermal Rating
-
Voltage
1~42kv
Chemistry
Organic Insulation
Classification
Organic Insulating Material
Certification
ISO9001
Type
Insulation Cover
Transport Package
Carton Box
Specification
Tee Interlaced Connection
Trademark
United Electric
Origin
P. R. China
HS Code
8547200000
Production Capacity
1000000PCS/Year

Product Description


UE-BBIC-TN1  Bus Bar Insulation Tee Interlaced Connection Cover / Bushing Boot up to 40.5kV
 
UE-BBIC-TN1 Bus Bar Insulation Tee Interlaced Connection Cover / Bushing Boot up to 40.5kV
UE-BBIC-TN1 Bus Bar Insulation Tee Interlaced Connection Cover / Bushing Boot up to 40.5kV

Bus bar insulation connection cover "UE-BBIC", A wide range of preformed covers are available for most of substation equipment connections. Customised covers can be made simply and economically by forming our insulation materials.
Installation is easy with no need to disconnect bus bars. Such covers are held in place with UV- stabilized plastic nuts and bolts, latches or cable ties, and be easily removed for maintenance. Suitable for applications up to 40.5kV.
Substation equipment is vulnerable to flashovers caused by accidental bridging of phases, or phase to earth. Usually made by birds, animals, vegetation or airborne debris, flashovers can be very expensive in terms of damage to equipment, reduced reliability. Most of event of this nature can be prevented by covering the strategically vulnerable bare metalwork.
Insulation for energized bus components and connections shall consist of tubing, tape, and other devices that are factory-engineered to meet applicable switchgear performcance requirements. UE bus bar connection covers "BBIC" provide high dielectric strength, adequate thermal endurance at bus operating temperatures, and tracking and erosion resistance.



Specification
 
Rated voltage 0.6/1(1.2)kV 8.7/15(17.5) kV 26/35(40.5) kV
Wall thickness 1mm 1.5-2mm 2.5-3.2mm

UE-BBIC-TN1 Bus Bar Insulation Tee Interlaced Connection Cover / Bushing Boot up to 40.5kVUE-BBIC-TN1 Bus Bar Insulation Tee Interlaced Connection Cover / Bushing Boot up to 40.5kV



Material test data
 
Property Test method Typical data
Tensile strength ASTM D 2671 ≥12MPa
Tensile strength after aging ASTM D 2671 (120°C /168hrs) ≥10MPa
Elongation at break ASTM D 2671 ≥400%
Elongation at break after aging ASTM D 2671 (120°C /168hrs) ≥300%
Dielectric strength IEC 243 ≥12kV/mm
Volume resistance IEC 93 ≥1012Ω.cm
Flammability IEC 60684-2 Method C 60sec max.
Low temperature flexibility ASTM D 2671 -40°C, 4hrs, no cracking
Water absirption ISO 62 (23°C /14days) <0.5%


Electrical test data
 
Test item Test method Test result
AC withstand 42kV, 1min No flashover or breakdown
Impulse voltage withstand 10 positive and 10 negative impulse of 75kV No flashover or breakdown


UE-BBIC-TN1 Bus Bar Insulation Tee Interlaced Connection Cover / Bushing Boot up to 40.5kVUE-BBIC-TN1 Bus Bar Insulation Tee Interlaced Connection Cover / Bushing Boot up to 40.5kVUE-BBIC-TN1 Bus Bar Insulation Tee Interlaced Connection Cover / Bushing Boot up to 40.5kVUE-BBIC-TN1 Bus Bar Insulation Tee Interlaced Connection Cover / Bushing Boot up to 40.5kVUE-BBIC-TN1 Bus Bar Insulation Tee Interlaced Connection Cover / Bushing Boot up to 40.5kVUE-BBIC-TN1 Bus Bar Insulation Tee Interlaced Connection Cover / Bushing Boot up to 40.5kVUE-BBIC-TN1 Bus Bar Insulation Tee Interlaced Connection Cover / Bushing Boot up to 40.5kVUE-BBIC-TN1 Bus Bar Insulation Tee Interlaced Connection Cover / Bushing Boot up to 40.5kVUE-BBIC-TN1 Bus Bar Insulation Tee Interlaced Connection Cover / Bushing Boot up to 40.5kVUE-BBIC-TN1 Bus Bar Insulation Tee Interlaced Connection Cover / Bushing Boot up to 40.5kVUE-BBIC-TN1 Bus Bar Insulation Tee Interlaced Connection Cover / Bushing Boot up to 40.5kVUE-BBIC-TN1 Bus Bar Insulation Tee Interlaced Connection Cover / Bushing Boot up to 40.5kVUE-BBIC-TN1 Bus Bar Insulation Tee Interlaced Connection Cover / Bushing Boot up to 40.5kVUE-BBIC-TN1 Bus Bar Insulation Tee Interlaced Connection Cover / Bushing Boot up to 40.5kV