Customization: | Available |
---|---|
Interface/Bushing: | Type C (EN50181) |
Rated Voltage: | 10kV, 20kV |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Test Item | Unit | CJBP20 / CJBKP20 | CJBP20 / CJBKP20 | CJBKP30 | CJBKP30 | CJBKP30 |
YH5WZ-26/66 | YH5W-30/85 | YH5WZ-34/85 | YH5W-36/121 | YH5W-45/118 | ||
Rated voltage ( Ur) | kV | 26 | 30 | 34 | 36 | 45 |
Continuous operating voltage (Uc) | kV | 20.8 | 24 | 27.2 | 28.8 | 36 |
AC reference voltage (U1mA) | kV | U1mA AC≥ 26 | U1mA AC≥ 30 | U1mA AC≥ 34 | U1mA AC≥ 36 | U1mA AC≥ 45 |
DC reference voltage (U1mA) | kV | ≥37 | ≥43 | ≥48 | ≥51.6 | ≥64.5 |
Leakage current under DC 0.75U1mA | μA | ≤50 | ≤50 | ≤50 | ≤50 | ≤50 |
Nominal discharge current | kA | 5 | 5 | 5 | 5 | 5 |
Steep current impulse residual voltage (Peak value) | kV | ≤76 | ≤98 | ≤95 | ≤139 | ≤136 |
8/20μs Lightning impulse residual voltage (Peak value) |
kV | ≤66 | ≤85 | ≤85 | ≤121 | ≤118 |
Switching impulse residual voltage (Peak value) | kV | ≤56 | ≤72.2 | ≤75 | ≤103 | ≤100 |
Long-duration current impulse, 2ms | A | 150 | 250 | 150 | 400 | 250 |
4/10μs high current impulse | kA | 65 | 65 | 65 | 65 | 65 |
Partial discharge | - | 21.8kV, ≤10pC | 25.2kV, ≤10pC | 28.6kV, ≤10pC | 30.3kV, ≤10pC | 37.8kV, ≤10pC |
Height (h) | mm | 286 | 318 | 345 | 345 | 420 |
Test Item | Unit | CJBP20, CJBKP20 | CJBP20, CJBKP20 | CJBP20, CJBKP20 | CJBKP30 | CJBKP30 | CJBKP30 |
YH10WZ-26/72 | YH10WZ-30/85 | YH10W-30/91 | YH10WZ-34/95 | YH10W-36/121 | YH10W-45/127.5 | ||
Rated voltage ( Ur) | kV | 26 | 30 | 30kV | 34 | 36 | 45 |
Continuous operating voltage( Uc) | kV | 20.8 | 24 | 24kV | 27.2 | 28.8 | 36 |
AC reference voltage (U1mA) | kV | U1mA AC≥ 26 | U1mA AC≥ 30 | U1mA AC≥ | U1mA AC≥ 34 | U1mA AC≥ 36 | U1mA AC≥ 45 |
DC reference voltage (U1mA) | kV | ≥37 | ≥43 | 43 | ≥48 | ≥51.6 | ≥64.5 |
Leakage current under DC 0.75U1mA | μA | ≤ 50μA | ≤50 | ≤ 20 | ≤50 | ≤50 | ≤50 |
Nominal discharge current | kA | 10 | 10 | 10 | 10 | 10 | 10 |
Steep current impulse residual voltage (Peak value) |
kV | ≤ 85 | ≤98 | ≤104 | ≤105 | ≤139 | ≤146.5 |
8/20μs Lightning impulse residual voltage (Peak value) | kV | ≤ 72 | ≤85 | ≤91 | ≤95 | ≤121 | ≤127.5 |
Switching impulse residual voltage (Peak value) |
kV | ≤ 65 | ≤64.9 | ≤77 | ≤85 | ≤103 | ≤108.5 |
Long-duration current impulse, 2ms | A | 400 | 400 | 350 | 400 | 400 | 400 |
4/10μs high current impulse | kA | 100 | 100 | 65 | 100 | 100 | 100 |
Partial discharge | - | 21.8kV, ≤10pC | 25.2kV, ≤10pC | 25.2kV, ≤10pC | 28.6kV, ≤10pC | 30.3kV, ≤10pC | 37.8kV, ≤10pC |
Height (h) | mm | 286 | 318 | 318 | 345 | 345 | 450 |