CJB20-2500/3T, CJB20-2500/4T, CJB20-2500/M 12kV, 24kV 1250A Outside Cone Screened Bus Bar System up to 24kV (Interface F)

Product Details
Customization: Available
Certification: RoHS, ISO9001, En50181
Rated Voltage: 12kV, 24kV
Diamond Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Years of Export Experience
The export experience of the supplier is more than 10 years
ODM Services
The supplier provides ODM services
OEM Services
The supplier provides OEM services for popular brands
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
to see all verified strength labels (23)
  • CJB20-2500/3T, CJB20-2500/4T, CJB20-2500/M 12kV, 24kV 1250A Outside Cone Screened Bus Bar System up to 24kV (Interface F)
  • CJB20-2500/3T, CJB20-2500/4T, CJB20-2500/M 12kV, 24kV 1250A Outside Cone Screened Bus Bar System up to 24kV (Interface F)
  • CJB20-2500/3T, CJB20-2500/4T, CJB20-2500/M 12kV, 24kV 1250A Outside Cone Screened Bus Bar System up to 24kV (Interface F)
  • CJB20-2500/3T, CJB20-2500/4T, CJB20-2500/M 12kV, 24kV 1250A Outside Cone Screened Bus Bar System up to 24kV (Interface F)
  • CJB20-2500/3T, CJB20-2500/4T, CJB20-2500/M 12kV, 24kV 1250A Outside Cone Screened Bus Bar System up to 24kV (Interface F)
  • CJB20-2500/3T, CJB20-2500/4T, CJB20-2500/M 12kV, 24kV 1250A Outside Cone Screened Bus Bar System up to 24kV (Interface F)
Find Similar Products

Basic Info.

Model NO.
CJB20-2500/3T, CJB20-2500/4T, CJB20-2500/M
Bushing Type
Type F (EN50181)
Application
MV GIS Switchboard Extended Accessories
Transport Package
Carton Box
Trademark
GCA
Origin
P. R. China
HS Code
8547900000
Production Capacity
1000000PCS/Year

Product Description


2500A Outside Cone Screened Bus Bar System up to 24kV (Interface F)
 
CJB20-2500/3T, CJB20-2500/4T, CJB20-2500/M 12kV, 24kV 1250A Outside Cone Screened Bus Bar System up to 24kV (Interface F)
CJB20-2500/3T, CJB20-2500/4T, CJB20-2500/M 12kV, 24kV 1250A Outside Cone Screened Bus Bar System up to 24kV (Interface F)

2500A Outside cone screened bus bar connectors are designed for connecting with type F interface bushing according to
EN50180, EN50181, DIN47636. Electrical specification according to standard of IEC 60502-4, IEC 62271-1.

CJB20-2500/M
CJB20-2500/M is a screened bus bar, made of silicone rub-ber and copper bar. The rated current is 2500/A, application for up to 24kV. The selection length of bus bar according to distance between bushings center.

CJB20-2500/4T
CJB20-2500//4T is a screened bus bar intermediate connector, made of silicone rubber, de-signed to connect with the bus bar CJB20-2500//M.

CJB20-2500/3T
CJB20-2500//3T is a screened bus bar end connector, made of silicone rubber, designed to connect with the bus bar CJB20-2500//M.



Selection guide

The standard length of L (distance between bushing center) is 600, 650, 750, 800, 900, 1200mm, other length is available
as requested.



CJB20-2500/3T, CJB20-2500/4T, CJB20-2500/M 12kV, 24kV 1250A Outside Cone Screened Bus Bar System up to 24kV (Interface F)

Technical data
 
Test Item Test value
AC voltage withstand 54kV, 5min
AC voltage withstand 65kV, 1min
Partial discharge 20kV, ≤5pC
Thundering impulse voltage withstand at 10 positive and 10 negative 125kV
Thermal short-circuit 31.5kA, 4s
Dynamic short-circuit 80kA

CJB20-2500/3T, CJB20-2500/4T, CJB20-2500/M 12kV, 24kV 1250A Outside Cone Screened Bus Bar System up to 24kV (Interface F)

Application

CJB20-2500/3T, CJB20-2500/4T, CJB20-2500/M 12kV, 24kV 1250A Outside Cone Screened Bus Bar System up to 24kV (Interface F)
CJB20-2500/3T, CJB20-2500/4T, CJB20-2500/M 12kV, 24kV 1250A Outside Cone Screened Bus Bar System up to 24kV (Interface F)

CJB20-2500/3T, CJB20-2500/4T, CJB20-2500/M 12kV, 24kV 1250A Outside Cone Screened Bus Bar System up to 24kV (Interface F)CJB20-2500/3T, CJB20-2500/4T, CJB20-2500/M 12kV, 24kV 1250A Outside Cone Screened Bus Bar System up to 24kV (Interface F)CJB20-2500/3T, CJB20-2500/4T, CJB20-2500/M 12kV, 24kV 1250A Outside Cone Screened Bus Bar System up to 24kV (Interface F)CJB20-2500/3T, CJB20-2500/4T, CJB20-2500/M 12kV, 24kV 1250A Outside Cone Screened Bus Bar System up to 24kV (Interface F)CJB20-2500/3T, CJB20-2500/4T, CJB20-2500/M 12kV, 24kV 1250A Outside Cone Screened Bus Bar System up to 24kV (Interface F)CJB20-2500/3T, CJB20-2500/4T, CJB20-2500/M 12kV, 24kV 1250A Outside Cone Screened Bus Bar System up to 24kV (Interface F)CJB20-2500/3T, CJB20-2500/4T, CJB20-2500/M 12kV, 24kV 1250A Outside Cone Screened Bus Bar System up to 24kV (Interface F)CJB20-2500/3T, CJB20-2500/4T, CJB20-2500/M 12kV, 24kV 1250A Outside Cone Screened Bus Bar System up to 24kV (Interface F)CJB20-2500/3T, CJB20-2500/4T, CJB20-2500/M 12kV, 24kV 1250A Outside Cone Screened Bus Bar System up to 24kV (Interface F)CJB20-2500/3T, CJB20-2500/4T, CJB20-2500/M 12kV, 24kV 1250A Outside Cone Screened Bus Bar System up to 24kV (Interface F)CJB20-2500/3T, CJB20-2500/4T, CJB20-2500/M 12kV, 24kV 1250A Outside Cone Screened Bus Bar System up to 24kV (Interface F)CJB20-2500/3T, CJB20-2500/4T, CJB20-2500/M 12kV, 24kV 1250A Outside Cone Screened Bus Bar System up to 24kV (Interface F)CJB20-2500/3T, CJB20-2500/4T, CJB20-2500/M 12kV, 24kV 1250A Outside Cone Screened Bus Bar System up to 24kV (Interface F)CJB20-2500/3T, CJB20-2500/4T, CJB20-2500/M 12kV, 24kV 1250A Outside Cone Screened Bus Bar System up to 24kV (Interface F)

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier